The cause of water after installing cold and dry equipment in screw air compressor

Time: 2022-10-29 Views: 582 times

Air storage tanks, dryers and filters will be installed after the screw air compressor, and the dryer can ensure that the screw air compressor reduces condensate in the production process and ensures the discharge of dry and clean air。If there will be water after being treated by the dryer, there are the following main reasons, and the specific content can be understood:

1, it may be that the air humidity around the screw air compressor station is large。We all know that the air itself has humidity, will contain a certain amount of water, when the air compressor, by the air compressor internal temperature is high, water directly evaporated to form water vapor, and then with the pressure discharged screw air compressor, such as shutdown, the temperature drops, will make water vapor condensate。Therefore, the operating environment humidity of screw air compressor should be low;Or before the screw air compressor is turned on and used, the condensate is discharged。

2, screw air compressor post-processing drying equipment failure。Generally, the pressure dew point of the dry dryer can be 3 ° C, assuming that the temperature of your work site is lower than 3 ° C, there will inevitably be water。Therefore, it is recommended to install an adsorption dryer as a post-treatment drying equipment, so that the pressure dew point can reach -20 ° C without water。
3, the post-treatment drying equipment equipped with screw air compressor can not operate normally。In general, the amount of post-drying treatment equipped by the manufacturer for the user is according to the uniform air consumption equipment, if your instantaneous gas consumption is larger, it will constitute the amount of post-treatment drying equipment is insufficient, resulting in water in the gas。
4, the gas tank itself has the function of water, which contains a lot of water is not discharged, or forget to drain。Periodically open the drain valve under the gas tank to drain the water。
5, air compressor pipeline planning problems。The planned inclination of the compressed air pipeline is not good, and the condensate water in the pipeline is not discharged in time, which will constitute water。

Copyright ©2020 Atlas Bolet (Le Le) All rights reserved Keywords: screw air compressor Oil free air compressor air compressor accessories

Technical support:Suzhou Shangyun Network Technology Co., LTD Record number:Shanghai ICP for 16021029